精品国产乱码久久久久久婷婷,国产传媒精品,亚洲AV日韩综合一区,久久国产成人

Pipe replacement and renovation
Oil water cooler tube replacement
Oil water cooler tube replacement
Oil water cooler tube replacement
Oil water cooler tube replacement

Oil water cooler tube replacement

Steam turbine oil-water cooler pipe replacement, marine oil-water cooler pipe replacement, chiller -304/316l stainless steel pipe replacement, condenser -304/316l stainless steel pipe replacement, heat exchanger -304/316l stainless steel pipe replacement, heat exchanger -304/316l stainless steel pipe replacement, shaft seal heater -304/316l stainless steel pipe replacement.
Online inquiry
  • Content details

Overview of replacing stainless steel pipes for oil-water coolers:


Lianyungang Lingdong Electromechanical Equipment Co., Ltd. is engaged in the transformation of oil-water cooler tubes and copper tubes into stainless steel tubes. 304/316l stainless steel tube heat exchange tubes have high resistance to vibration, scaling, and corrosion. Stainless steel tube heat exchange tubes have overcome the industry's previous challenges of reducing wall thickness to enhance heat transfer or using rolling screws on the tube wall to weaken tube stiffness, resulting in reduced wall thickness, enhanced heat transfer, and increased stiffness, Simultaneously possessing anti vibration and anti scaling properties.


Introduction to replacing stainless steel pipes with welded steel pipes for oil-water coolers:


Welded steel pipes (also known as slotted pipes and welded pipes) for replacing pipes in oil-water coolers are mainly used in auxiliary machinery in industries such as thermal power generation, chemical industry, and steel, such as condenser and heater pipe replacement, tubular oil-water cooler pipe replacement, oil-water cooler pipe replacement, tubular oil-water cooler pipe replacement, Le tube cooler pipe replacement, turbine oil-water cooler pipe replacement, marine oil-water cooler pipe replacement, chiller -304/316l stainless steel pipe replacement, Condenser - replace 304/316l stainless steel tubes, heat exchanger - replace 304/316l stainless steel tubes, heat exchanger - replace 304/316l stainless steel tubes, shaft seal heater - replace 304/316l stainless steel tubes, steam seal heater - replace 304/316l stainless steel tubes, low-pressure heater - replace 304/316l stainless steel tubes, air preheater tubes, air cooler tubes, air cooler tubes, waste heat recovery device tubes, and volumetric heat exchanger tubes, Energy harvester tube replacement and related tube bundle tube replacement. Oil water cooler tube replacement, oil water cooler tube replacement, stainless steel tube heat exchange tube specification: diameter Ф 12~ Ф 32mm, with a wall thickness of 0.6-3.0mm. The deviation value of the pipe wall thickness is ± 0.05mm, and there are two types of lengths: fixed length and indefinite length- The types of stainless steel pipes used include 304, 304L, 316, 316L, 317, and 317L.


The main modifications for the oil water cooler tube and core replacement are:


When selecting an oil-water cooler for tube and core replacement, the cooling area should be informed, and the cooling forms can be divided into LY type light tube (- use) and LYC type fin type. Stainless steel tubes are generally selected for heat exchange and cooling, and purple copper, brass, and titanium tubes can also be selected as heat exchange components according to user needs. According to the trend of economy, heat transfer, and results, most power plants choose to replace stainless steel tube bundles, which has a certain potential without reducing the rate! The replacement of stainless steel pipes for oil-water coolers is the mainstream choice for pipe and core replacement in power plants


The function of oil-water cooler:


During the normal operation of the steam turbine generator set, some power is consumed due to bearing friction. The oil-water cooler will convert heat to increase the lubricating oil temperature of the bearings. If the oil temperature is too high, the bearings may experience softening, deformation, or burning accidents. In order to ensure the normal operation of the bearing, the lubricating oil temperature must be maintained within a certain range. Generally, the oil temperature entering the bearing should be between 35-45 ℃, and the discharge oil temperature of the bearing should rise to 10-15 ℃. Therefore, the oil discharged from the bearing must be cooled before it can be recycled into the bearing lubrication. The auxiliary oil-water cooler is used to cool the lubricating oil of the main engine. High temperature lubricating oil and low temperature cooling water undergo heat exchange in the oil-water cooler, and the purpose of controlling the lubricating oil temperature is achieved by adjusting the cooling water flow rate (at the same time, due to the high rotor temperature, especially on the inlet side of the high-pressure cylinder, the journal of the oil-water cooler also transfers heat outward, so the lubricating oil also has the function of cooling the journal). In order to ensure sufficient safety and recovery of turbine oil cooling during turbine operation, the dual oil water cooler consists of two oil water coolers with the same area and a three-way valve, which can only work and be used as a backup. If the cooling effect is poor due to high oil temperature or high inlet water temperature of the unit, or when cleaning and repairing the oil water cooler is required during operation, the backup oil water cooler can be opened without shutting down.


Series and parallel - missing -:


1. The series operation of oil-water coolers includes cooling and uniform oil temperature.


2. Shortcomings in series operation of oil-water coolers: high pressure drop in oil, inability to 刪除late oil during operation.


3. The parallel operation of the oil-water cooler has a small decrease in oil pressure, convenient 刪除lation, and can be repaired during operation.


4. The shortcomings of parallel operation of oil-water coolers include poor cooling performance and uneven oil temperature.


Classification and specifications of stainless steel pipes for replacing oil and water coolers:


The classification specifications include stainless steel pipes, stainless steel threaded pipes, stainless steel corrugated pipes, 304 stainless steel pipes, 316L stainless steel pipes, etc. The stainless steel heat exchange pipes developed by Lianyungang Lingdong Electromechanical Equipment Co., Ltd. are made of high-quality stainless steel pipes.


Process flow of stainless steel welded pipes:


Stainless steel strip, formed by cold drawing, hot drawing, and strip steel, is produced and processed through a series of processes such as coiling, welding, flaw detection, rolling, polishing, solid melting, and polishing for 304 stainless steel pipes and 316L stainless steel pipes; We can produce various stainless steel pipe specifications such as different pipe diameters, wall thicknesses, and length forms according to the needs of users.


Process requirements for replacing stainless steel pipes in oil-water coolers:


1. Preparation of stainless steel pipe: Cut the qualified stainless steel pipe according to the size of the oil-water cooler. The stainless steel pipe should be 4-5 millimeters longer than the pipe plate. Remove burrs from both ends of the stainless steel pipe, polish the expanded part of the pipe smooth, and perform tempering treatment at about 50 millimeters at both ends.


2. Remove old stainless steel tubes: Use a semi-circular triangular chisel to remove them. When removing, be careful not to damage the tube plate. Polish the stainless steel tube, remove the old stainless steel tube, clean the tube plate hole, polish it with a fine sandcloth, and wipe off the dust with a cloth.


3. Pipe threading and expansion: After both the pipe plate and stainless steel pipe are prepared, they can be threaded through the stainless steel pipe. Be careful not to use too much force or force, align them with your own hole position, and install them. The exposed parts at both ends of the pipe should be equal. The diameter of the pipe plate hole is slightly larger than the pipe diameter, about 0.5 millimeters, and should not be too large or too small. After the stainless steel pipe is threaded, a pipe expander can be used to expand the mouth. When expanding the pipe, the force and speed should not be too large or too small. The length of the expanded pipe should be 2/3 of the thickness of the pipe plate, and should not be greater than the thickness of the pipe plate. After the expansion is completed, both ends should be flanged with a punch.


4. When replacing stainless steel pipes, it is necessary to replace them half by half, and then disassemble the other half.


5. The welded joint after pipe replacement needs to undergo leakage or damage testing.


6. The oil and water cooler tube and core replacement renovation basically involves dismantling and shipping the entire oil and water cooler equipment to our company for tube bundle replacement. This is more economical than on-site tube replacement - it increases the speed of tube and core replacement. The replacement speed of the oil-water cooler is slow during the production time of the pipes, as they are all customized. After the pipes are replaced, the assembly speed of the replacement pipes can be completed in 3-5 days!


The oil and water cooler uses welded stainless steel pipes (also known as straight seam pipes) for pipe replacement


The welded steel pipe used for the replacement of the oil-water cooler is manufactured using imported pipe manufacturing equipment, which is equivalent to or slightly stronger than stainless steel pipes. The metallographic structure of the weld seam and the mechanical properties such as the base material sample and strength are also slightly different. Due to the uniform thickness and smooth surface of the stainless steel pipe strip, it is indeed better than cold drawn, hot rolled, and seam stainless steel pipes of the same material. The elongation is greater than 35%, and the hardness is small, making it easy to expand and connect.


The replacement of stainless steel pipes for oil-water coolers has the following features:


1. Stainless steel tube heat exchange tube heat transfer energy. Due to the use of thin-walled stainless steel tubes with a wall thickness of 0.5-0.7mm, the overall heat transfer energy is improved. Under the same heat exchange area, the overall heat transfer coefficient is 2.124-8.408% higher than that of copper tubes.


2. Due to the use of American standard AISl304, 316l and other stainless alloy steels for the pipes, they have high hardness and the rigidity of stainless steel pipes is also significantly improved. Therefore, it has strong impact energy and anti vibration energy of high-temperature steam.


3. Due to the smooth inner wall of stainless steel pipes, the thickness of the bottom layer of the boundary laminar flow is reduced, which not only enhances heat transfer but also improves the ability to resist scaling.


4. Oil water cooler tube exchange, oil water cooler tube exchange, stainless steel tube heat exchange tube process, using the expansion tube technology of transmission, the outer diameter tolerance of stainless steel tube is the same as that of copper tube, without changing the machining tolerance of tube plate hole, which is conducive to on-site direct selection and convenient for unit oil water cooler tube exchange.


5.304/316l stainless steel heat exchange tubes are economical. Under the same heat exchange area, the cost of stainless steel tubes is about 80% of the cost of copper tubes, and can be directly transformed into tube bundles.


In order to eliminate welding stress on heat exchange tubes, heat treatment is carried out at a high temperature of 1050 ℃ under protective gas.


7. All pipes are subjected to pressure difference method for leakage inspection, with a pressure test reaching 1.0Mpa and a pressure drop of 5 minutes.


Oil water cooler pipe replacement, oil water cooler pipe replacement, stainless steel pipe structure ---:


1. Heat transfer energy difference, due to the use of thin-walled stainless steel tubes with a wall thickness of 0.5-0.8mm, the heat transfer energy is improved. Under the same heat transfer area, 304/316L stainless steel heat transfer tubes are about 1.2-1.30 times larger than copper tubes


2. Strong corrosion resistance, corrosion resistance, ammonia corrosion, and general corrosion. 304/316L stainless steel heat exchange tubes can be used for more than 10 years.


3. Due to the use of high-energy stainless alloy steels such as TP304 and TP316L as stainless steel materials, the surface has high strength, and the inner wall of the pipe is smooth, which reduces the thickness of the boundary laminar flow layer. Therefore, it has strong high-temperature steam erosion energy.


4. The rigidity and vibration resistance of the pipe are improved.


5. Strengthening the heat exchange tube has improved the ability to resist scaling.


6. The process of installing stainless steel heat exchange tubes can be achieved by using the expansion tube technology of transmission. The outer diameter tolerance is consistent with the steel pipe, and there is no need to change the machining tolerance of the tube plate hole, which is conducive to direct selection and convenient for replacing stainless steel tubes with copper tubes in the unit


7. Economically, under the same heat exchange area, the cost is about 60% of copper tubes, and stainless steel heat exchange tubes can be directly used for tube exchange.


8. Stainless steel heat exchange tubes are made by highly automated pipe making equipment, which is formed by self corrosion solution welding and flipping. Under any metal filler, they are filled with gas protection (inner and outer sides of the tube) and welded. The welding method is TIG process and undergoes in solution eddy current testing.


9. In order to eliminate the stress on the pipe, heat treatment can be carried out at a high temperature of 1040 ℃ under protective gas, or time-vibration treatment can be carried out as needed.


10. All steel pipes shall be subjected to water pressure pneumatic testing one by one, and the pressure shall be tested to within 10Mpa for 10 seconds before depressurization.


11. After leaving the factory, conduct eddy current testing on each tube, with a frequency of 10-30 kHz.


12. The outer diameter deviation of the pipe is generally ± 0.10mm, the wall thickness deviation is ± 10%, and the length deviation is ± 5mm.


13. All pipes shall be checked for their full length using a gauge.


14. The raw materials entering the factory and the finished products being shipped are both tested and a test report is issued.


The general principle for selecting pipes for tube bundle replacement is:


1. No severe corrosion leakage, use as long as possible, erosion and wear, vibration resistance, high heat transfer coefficient, and reasonable structure. For decades, copper pipes have been used in my condensers, oil-water coolers, chillers, and more, due to their high thermal conductivity.


2. In practice, some copper pipes of the condenser are subjected to severe ammonia corrosion, while others are subjected to severe wear and tear. These two phenomena cause copper pipes to leak tightly, greatly reducing the use of copper pipes, reducing the safety and economy of unit operation, and increasing the time for shutdown and replacement of copper pipes. Therefore, many people have started to consider the issue of condenser pipe materials.


In recent years, stainless steel heat exchange tubes have been widely used in condensers, oil-water coolers, air coolers, low-pressure heaters, high-pressure heaters, air coolers, heat exchangers, chillers, and air preheaters. According to incomplete calculations, the units used are over 50%, including 50-300MW units. The use of 304/316l stainless steel heat exchange tubes has broken the traditional concept of only using copper tubes, improved equipment safety and economy, and reduced investment.


However, there are still many people who lack interest in using stainless steel heat exchange tubes for oil-water cooler tube exchange. The main reason is that the thermal conductivity of stainless steel tube heat exchange tubes is much lower than that of copper tubes, which may affect heat transfer. For this reason, relevant units have conducted many studies on the overall heat transfer coefficient of stainless steel heat exchange tubes used in condensers, and have achieved great results. More and more power plants are replacing copper pipes with stainless steel pipes.


Cooling equipment - using stainless steel heat exchange tubes (cooling tubes):


Stainless steel heat exchange tubes and cooling tubes are produced using advanced automation, technology, and process. Select ASTM 304 and 316L standard stainless steel materials for good processing and production.


Stainless steel pipes are used for replacing the oil water cooler pipes -


-High temperature steam, erosion resistance, anti scaling, anti oxidation corrosion, strong vibration resistance, and wear resistance.


Heat exchange - material -, thin tube wall, smooth inner wall, and enhanced heat transfer.


Safety: High temperature steam, erosion resistance, strong vibration resistance.


Economy - Same heat exchange area, cost savings (about 80/100 of copper pipes).


Summary - Internal and external design and operation experience. Compared with brass pipes, the welding of stainless steel heat exchange pipes in oil-water coolers has the following advantages:


1. Stainless steel heat exchange tubes are three times more corrosion-resistant, vibration resistant, and wear-resistant than copper tubes, and can be used;


2. Stainless steel pipes are not easy to stain or scale, and can last for 10-20 years;


3. Although the thermal conductivity of stainless steel heat exchange tubes is inferior to that of copper, the wall thermal resistance only accounts for 3% to 5% of the total thermal resistance. Due to the increase in water velocity inside the pipe, the increase in cleanliness coefficient, and the decrease in wall thickness, the heat transfer energy of stainless steel is higher than that of copper alloy;


4. The manufacturing technology, specifications, performance indicators, inspection methods, and scale of the inner thin-walled welded oil-water cooler tube replacement have all reached an international level;


5. The thermal conductivity coefficient of stainless steel pipes is lower than that of copper pipes, but the difference in thermal conductivity coefficient is reduced by reducing the wall thickness. Due to the smoother inner wall compared to copper pipes, the convective heat transfer coefficient is higher than copper pipes, and the smoother outer wall compared to copper pipes, the condensation heat release coefficient is higher than copper pipes. According to the testing and calculation of one unit, the overall heat transfer coefficient of stainless steel pipes with a wall thickness of 0.7mm is about 2.124% higher than that of copper pipes with a wall thickness of 1mm;


6. As the operating time increases, the overall heat transfer coefficient of stainless steel pipes decreases slowly, while the overall heat transfer coefficient of copper pipes decreases much faster than that of stainless steel pipes. In the long run, using it as a whole improves the economy of the unit, while also improving the safety of the unit.


Instructions for ordering oil water cooler tube and core replacement renovation:


1) Model of steam turbine unit


2) Cooling oil quantity


3) Cooling area of oil cooler


4) Oil water cooler model


5) Do you need to replace the pipes of the oil-water cooler? Or replace the core of the oil-water cooler (replacing the core means replacing the tube plate, partition, and tube)?


6) The quantity, wall thickness, and length dimensions of the replacement pipes for the oil-water cooler.


7) The replacement of pipes for oil-water coolers requires the provision of chloride ion content in the water quality used.


Oil water cooler model parameters:

汽輪機(jī)規(guī)格冷油器型號(hào)冷卻面積
(m2)
冷卻油量
(t/h)
進(jìn)油設(shè)計(jì)溫度
(℃)
出油設(shè)計(jì)溫度
(℃)
設(shè)計(jì)水量
(t/h)
配套臺(tái)數(shù)-高工作水溫
(℃)
N1.5MWLY-10108554525133
N3MWLY-10108554525233
N6MWLY-12.512.58.7554525233
N12MWLY-17.517.512.6554530233
N15MWLY-202012.6554530233
N20MWLY-303027554565233
N25MWLY-353530554585233
N30MWLY-424236.95545102233
N50MWLY-4848405545112233
N100MWLY-5555475545135233
N125MWLY-606052.85545150233
N135MWLY-606052.85545150233
N200MWLY-7575725545170233
N300MWLY-95951205545200233













































以下304不銹鋼管/316L不銹鋼管換熱管規(guī)格技術(shù)參數(shù)僅供參考,詳細(xì)參數(shù)電話咨詢我們!以實(shí)際管束為準(zhǔn),可按客戶要求設(shè)計(jì)相應(yīng)管束!
材料OSIMNPSNICRMOn-2000n-4200
304≤≤0.0800.752.000.0400.0308.00-11.0018.00-20.00-20004200
304L≤0.0350.752.000.0400.0308.00-13.0018.00-20.00-

316≤0.0800.752.000.0400.03010.00-14.0016.00-18.002.00-3.0083009600
316L≤0.0350.752.000.0400.03010.00-15.0016.00-18.002.00-3.0045007043

NOHFCOAIV317441504680
不銹鋼管∠∠0.020.050.0150.250.122.5-3.52.0-3.0


型號(hào)
1Φ14×0.5Φ14×0.6Φ14×0.7Φ14×0.8


2Φ15×0.5Φ15×0.6Φ15×0.7Φ15×0.8


3Φ16×0.5Φ16×0.6Φ16×0.7Φ16×0.8


4Φ18×0.5Φ18×0.6Φ18×0.7Φ18×0.8


5Φ19×0.5Φ19×0.6Φ19×0.7Φ19×0.8


6Φ20×0.5Φ20×0.6Φ20×0.7Φ20×0.8Φ20×1.0

7Φ22×0.5Φ22×0.6Φ22×0.7Φ22×0.8Φ22×1.0Φ22×1.2
8Φ25×0.5Φ25×0.6Φ25×0.7Φ25×0.8Φ25×1.0Φ25×1.2Φ25×1.5
9Φ26×0.5Φ26×0.6Φ26×0.7Φ26×0.8Φ28×1.0Φ28×1.2Φ28×1.5
10
Φ30×0.6Φ30×0.7Φ30×0.8Φ30×1.0Φ30×1.2Φ30×1.5
11

Φ32×0.7Φ32×0.8Φ32×1.0Φ32×1.2Φ32×1.5

不銹鋼管各種型號(hào)化學(xué)成分對(duì)照表:
管材型號(hào)規(guī)格磷?
(P)

(S)
硅?
( Si )
鎳?
( Ni )
鉻?
(CR )
鉬?
(Mo)
CMn
304≤0.08≤2.00≤0.035≤0.03≤0.1≤8.00-10.50≤18.00-20.00
304L≤0.03≤2.00≤0.035≤0.03≤0.1≤9.00-13.00≤18.00-20.00
316≤0.08≤2.00≤0.035≤0.03≤0.1≤10.00-14.00≤16.00-18.002.00-3.00
316L≤0.03≤2.00≤0.035≤0.03≤0.1≤10.00-14.00≤16.00-18.002.00-3.00









銅管與不銹鋼管換熱遙遙能對(duì)照表:
名稱

規(guī)格材質(zhì)總體換熱系數(shù)(W/m2.k)不銹鋼管與銅管比
總體換熱系數(shù)提高%




銅管

1.0(mm)HSn70-1A3682.4138690

不銹鋼管

1.0(mm)304,304l,316,316L3460.327347-6

不銹鋼管

0.7(mm)304,304l,316,316L3760.6284762.214

不銹鋼管

0.6(mm)304,304l,316,316L3872.6067295.214

不銹鋼管

0.5(mm)304,304l,316,316L3992.0159688.408










介質(zhì)水-適應(yīng)氯離子含量指標(biāo)對(duì)照表:
管材

H68-AHSn70-1TP304,TP304LTP316,TP316LTP317,TP317L


長(zhǎng)期遙遙
氯離子含量
(mg/L)


≤50≤100≤150≤300≤500
短期遙遙
氯離子含量
(mg/L)


≤100≤200≤300≤500≤1000











zanpc zanpchover
wechat 分享到微信
wechat 分享到微信
weibo 分享到微博

產(chǎn)品動(dòng)態(tài)

打賞
手機(jī)看全文
手機(jī)掃碼看全文
分享
微信好友
復(fù)制鏈接
掃碼分享至微信

Copyright ? 2012-2023 Lianyungang Lingdong Electromechanical Equipment Co., Ltd all rights reserved

Tel

0518-85370171

亚洲中文字幕无码一区二区三区| 最新超碰| 国产激情精品| 色婷婷久久久| 国产乱码| 国产av午夜精品一区二区三| 成在人线av无码免费高潮水老板| 精品国产一区AV天美传媒| 巨爆乳中文字幕爆乳区| 国产在线高清精品二区| 精品久久久久久综合另类小说| 国产偷亚洲偷欧美偷精品| 乱码丰满人妻一区二区| 男女啪啪网址| 蜜桃av精品少妇人妻天美传媒| 这里只有精品| 国产精品人成在线播放新网站| 亚洲中文字幕无码久久综合网 | 丰台区| 国产乱子伦农村叉叉叉| 久人人爽人人爽人人片av| 羞羞影院午夜男女爽爽视频免费| 亚洲欧美日韩一区在线观看| 亚洲不卡av一区二区三区| 狠狠狠狠一本区| 无限高潮91ropn九色| 毛片免费观看| 久久久久成人精品无码中文字幕| 精品人妻中文无码AV在线| 无码久久精品国产亚洲AV影片| 国产成人亚洲综合精品| 国产精品区一区二区三在线播放| 国产成人综合色视频精品| 久久无码专区外国精品| 欧美日韩免费在线| 欧美日韩免费观看| 18禁无遮挡羞羞啪啪免费网站| 女同久久精品国产99国产精品 | 亚洲日本VA午夜中文字幕一区| 久久国产精品高清| 黄色网页入口|